The equipment is suitable for applicability test of electronic product,car element,part and materials under high and low Temperature when being stored, transported and used.
Reference Standards
Model |
WTH40 |
WTH60 |
WTH80 |
WTH120 |
WTH160 |
WTH180 |
WTH230 |
WTH290 |
WTH310 |
WTH390 |
WTH470 |
|||||||||
Nominal volume(m³ ) |
3.9/3.4 |
6.3/5.5 |
7.8/6.8 |
11.7/10.2 |
15.6/13.6 |
17.5/15.3 |
23.3/20.4 |
29.2/25.5 |
31.1/27.2 |
38.9/34.0 |
46.7/40.8 |
|||||||||
Temperature range |
-60℃ -100℃ (optional-70℃ -120℃ /-70℃ -150℃) |
|||||||||||||||||||
Humidity range |
20% RH~98% RH/(20~85℃) |
|||||||||||||||||||
Temperature fluctuation |
± 0.5℃ |
|||||||||||||||||||
Temperature deviation |
± 2℃ |
|||||||||||||||||||
Humidity deviation |
± 3.0%RH(≧ 75% RH); ± 5.0%RH(≦ 75% RH) |
|||||||||||||||||||
Warm-up time |
25℃~+100℃(optional 120℃, 150℃) |
|||||||||||||||||||
≦ 25MIN |
≦ 28MIN |
≦ 28MIN |
≦ 30MIN |
≦ 31MIN |
≦ 32MIN |
≦ 34MIN |
≦ 36MIN |
≦ 38MIN |
≦ 41MIN |
≦ 45MIN |
||||||||||
Cooling time |
+25℃ rated limit low temperature, 30min~180min (it is different according to different models and configurations) |
|||||||||||||||||||
Internal size(mm) |
W |
1800 |
2700 |
3600 |
||||||||||||||||
H |
I: 2100 II: 2400 |
|||||||||||||||||||
D |
900 |
1450 |
1800 |
1800 |
1800 |
2700 |
3600 |
4500 |
3600 |
4500 |
5400 |
|||||||||
Temperature and humidity regulating mode |
BT(H)C balance temperature regulation(humidity regulation)manner |
|||||||||||||||||||
Temperature of using environment |
+5℃ ~ +35℃ |
|||||||||||||||||||
Protection building envelope |
Spraying plastics galvanizing color steel plate, temperature resistant stress thermal insulation material, SUS304 stainless steel composite assembly plate |
|||||||||||||||||||
Regulator |
Heater |
Nicochrome fin heating tube |
||||||||||||||||||
Humidifier |
Stainless steel armored heater(steam humidifying or external humidifying, the ultrasonic humidifier is installed according to the demands) |
|||||||||||||||||||
Fan |
Centrifugal fan |
|||||||||||||||||||
Refrigerating fluid |
Mechanical compressor |
|||||||||||||||||||
Refrigerating fluid |
R404a or R404a /R23 |
|||||||||||||||||||
Refrigerating mode |
Minimum test temperature≥ -25℃: water cooling mechanical compression single refrigeration mode: minimum test temperature≦ -40℃, water cooling mechanical compression binary cascade refrigeration mode |
|||||||||||||||||||
Controller |
Display |
Above 7.0 inch, TFT color LCD display |
||||||||||||||||||
Operation mode |
Program operation, fixed value operation |
|||||||||||||||||||
Setting mode |
Chinese menu, input by touch screen |
|||||||||||||||||||
Program capatity |
Number of editable program: 99 maximum; step: 999 steps; cycle number: 99 maximum |
|||||||||||||||||||
Setting range |
Temperature: adjust according to the temperature range of the equipment(upper limit+5℃;Lower limit: -5℃; lower limit: -5℃); humidity: 0%RH-100%RH(humidity and temperaure test equipment) |
|||||||||||||||||||
Display resolution |
Temperature: 0.01℃; time: 0.1min; humidity; 0.1%RH(temperature and humidity test equipment) |
|||||||||||||||||||
Input |
Thermal resistance and thermocouple |
|||||||||||||||||||
Communication function(purchasing) |
RS-485 interface with local and remote communication function, monitoring software, RS-485/RS-232 convertor, one COM interface and one USB interface occupying PC computer; connect 16 sets of equipment at most; and the maximum accumulated length of the cable is 800M |
|||||||||||||||||||
Control mode |
Anti-integration saturation PID |
|||||||||||||||||||
Curve recording function |
RAM with battery protection: it can save the setting value, sampling value and sampling time of equipment; and the maximum recording time is 350 days(when the sampling period is 1.5min) |
|||||||||||||||||||
USB function |
It is equipped with one U-disk and software disk special for PC computer(applicable for complex Chinese, English WINDOWS operation system); the test program is compiled by PC special software and saved in U-disk; and then the test program is tuned out from the U-disk and saved in the controller; or the program in the controller is saved in U-disk and then it is saved in PC machine to be analyzed and managed.The test curve data saved in the controller can be saved in U-disk.The test data/curve is directly printed and displayed by PC special software; or the recorded data is converted to Access data file read by Microsoft Office.The test curve data recorded by the recorder is as follows: two-circuit temperature-seting temperature and actual temperature; two-circuit humidity-setting humidity and actual humidity(if the equipment has humidity function); record the time. |
|||||||||||||||||||
Auxiliary function |
Fault alarm and reason, treatment prompt function, power failure protection function, and upper and lower temperature limit protection function; calendar timing function(automatic starting or automatic stopping); self-diagnostic function |
|||||||||||||||||||
Water supply |
Humidity system |
Equipped with muli-level filter reverse osmosis water purifier(users provide humidification water with resistance rate ≥ 500Ω m |
||||||||||||||||||
Cooling circulating water |
Water supply pressure: 0.32~0.45MPa water temperature: ≤ 30℃ |
|||||||||||||||||||
Power |
AC 380V(± 10%)V 50HZ three-phase four-wire+protection ground wire |
|||||||||||||||||||
Installed capacity |
20KW~55KW(it is different according to different models and configurations) |
|||||||||||||||||||
Standard configuration |
Observation window, wire hole, floodlight, time accumulator, one power wire(6m long), one sample power control terminal, one RS-485-232 interface, one USB and one U-disk |
|||||||||||||||||||
Safety device |
Refrigerating system: over-voltage of compressor, over-heating of compressor, over-current of compressor motor, water supply and under-voltage of cooling water(water cooling); humidifying system(SQW model): dry burning of heating tube, abnormal water supply and abnormal water drainage.Test chamber: over-temperature protection, temperature fuse wire, over-heating of fan and motor, others: phase sequence of total power and lacking protection, leakage protection and load short circuit protection. |
Let's get to know each other